Water at the base of the wall: Kalkallo handover findings

Low weep holes, weeps full of mortar, unsealed expansion joints and paths without isolation joints, all from Kalkallo handovers.

  • Kalkallo 3064
  • 22 September 2026
  • 3 min read
Request your quotePick the inspection and leave your number. We ring back the same working day.

No obligation. We use your details for your quote and may contact you about it even if you don't finish.

Fully licensed & accredited

In short: The finishes inside get the attention at handover. The details where wall meets ground decide whether water stays out for the next twenty years.

Weep holes too close to the ground

At a Kalkallo handover in December 2025 the weep holes sat less than 150mm above the ground beside them. Paving and soil had been finished too high.

And weep holes full of mortar

At another job they were blocked with mortar and render from the bricklayer. A blocked weep cannot drain the cavity behind the bricks.

Joints left open

Expansion joints in the brickwork were unsealed and still holding mortar, and pipes passing through external walls had no caulking. Each is a small path for water into the wall.

Paths poured hard against the slab

One house had no isolation joint between the path and the slab, which invites cracking where the two meet. All of these are the builder's to fix before the keys change hands.

Written by our local inspection team from work carried out in Kalkallo. Licensed building practitioners, Building & Plumbing Commission registration CDB-U 53425.

Blog

More from the Kalkallo blog

All posts →

Book a building inspection in Kalkallo

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Questions Kalkallo owners ask about this

Who fixes weep hole clearance?

At handover, the builder. Later, it usually falls to you.

Are these structural defects?

No, but they are the details that let water in over time.

CallGet a Free Quote